Weidmuller UPIR - Analog to frequency converter Manuale Utente

Navigare online o scaricare Manuale Utente per Hardware Weidmuller UPIR - Analog to frequency converter. Weidmuller UPIR - Analog to frequency converter Benutzerhandbuch Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 28
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 0
de
en
UPI/R 61001034/00/02.08
Bedienungsanleitung
Analog-Frequenz-Wandler
mit Hilfsstromversorgung und
Grenzwertüberwachung 3
Operating instructions
Analogue frequency converter
with auxiliary current supply and
threshold monitoring 15
Vedere la pagina 0
1 2 3 4 5 6 ... 27 28

Sommario

Pagina 1 - Operating instructions

deenUPI/R 61001034/00/02.08BedienungsanleitungAnalog-Frequenz-Wandler mit Hilfsstromversorgung und Grenzwertüberwachung 3Operating instructionsAna

Pagina 2

10• KonfigurationKonfiguration ändernZum Aufrufen des Konfigurationsmodus schließen Sie die Sicherheitsverbindung an, und drücken Sie die Tasten Å und ì

Pagina 3

11InputCalibration?CIPnCIPyEingangskalibrierung überspringenEingänge kalibrierenToggle AcceptTransfer functionFnC=LInrSrAngabe der Übertragungsfunktio

Pagina 4 - • Betrieb

12Deadband valuedb1=0.1Totband, z. B. 0,01 %- Dec- IncNextAcceptTimer delaydL1=20Zeitverzögerung (inaktiv bei Setzen auf 0 s), z. B. 20 s- Dec- IncNex

Pagina 5

13• KalibrierungAllgemeinDas UPI/R ist werksseitig kalibriert. Das kalibrierte Gerät kann mit jedem Eingangssignalformat betrieben werden. Führen Sie

Pagina 6

14Vorgehensweise bei der EingangskalibrierungAnzeige Aktion/Beschreibung ENTïAktivieren Sie den Konfigurationsmodus des Gerätes, und scrollen Sie durch

Pagina 7

15en UPI/RContentsOperation 16Installation 17Setup 21Calibration 23

Pagina 8

16en UPI/R• OperationGeneralThe UPI/R converts a current or voltage signal to a pulse rate proportional to the input signal level. It also has a displ

Pagina 9

17Reviewing the setupFor review mode, press the Å and ì keys simultaneously. Press the Å and ì keys to move through the setup sequence (see table). Gr

Pagina 10 - • Konfiguration

184-wire voltagetransmitter(+) 4(-) 32-wire (loop powered)transmitter(+) 1(-) 24-wire currenttransmitter(+) 2(-) 3InputSignalPower supplyLive (+)Neutr

Pagina 11

19ConnectionsStrip wires to 7 mm from the ends. Use a suitable ferrule for multi-stranded wires (do not solder).Use 12-28 AWG Cu Wire rated for temper

Pagina 13 - • Kalibrierung

20Power Supply RequirementsCheck the power supply against the model number before applying power to the instrument. Micromann modules must be used wit

Pagina 14 - Å oder ì

21• SetupChanging the setupFor setup mode, connect the security link and press the Å and ì keys simultaneously. The software version will be displayed

Pagina 15

22Low cut-out settingsCO=yCO=nEnable low cut-outDisable low cut-outToggle AcceptCOP=2.50Introduces cut-off level in %,e.g., 2.50 %- Dec- IncNextAccept

Pagina 16 - • Operation

23• CalibrationGeneralThe UPI/R is factory calibrated. Once calibrated it will operate with any input format. Allow the instrument 15 minutes of power

Pagina 17 - • Installation

24Input calibration procedureWhen thedisplay showsAction/Description ENTïPut the instrument in setup mode and scroll through the main menuCIPnPress Å

Pagina 21 - Å and ì

Weidmüller Interface GmbH & Co. KGPostfach 303032720 DetmoldKlingenbergstraße 1632758 DetmoldTel. +49 5231 14-0Fax +49 5231 14-20 83info@weidmuell

Pagina 22 - Setup Sequence (continued)

3de UPI/RInhaltsverzeichnisBetrieb 4Installation 7Konfiguration 10Kalibrierung 13

Pagina 23 - • Calibration

4de UPI/R• BetriebAllgemeinDas UPI/R wandelt ein analoges Strom- oder Spannungssignal in eine zum Eingangssignalpegel proportionale Impulsrate um. Es

Pagina 24 - Input calibration procedure

5Überschreitung des AnzeigebereichsLiegt das Eingangssignal außerhalb des programmierten Eingangsbereichs, erscheint in der Anzeige Ovr bei Bereichsüb

Pagina 25

64-Draht-Spannungs-Transmitter(+) 4(-) 3(schleifengespeister) 2-Draht-Transmitter(+) 1(-) 24-Draht-Strom-Transmitter(+) 2(-) 3EingangSignalStromversor

Pagina 26

7AllgemeinDie Installation dieser Geräte darf nur von speziell ausgebildetem Fachpersonal, unter Beachtung der in dieser Dokumentation enthaltenen Inf

Pagina 27

8Klemme Signal124 V DC (Ausgang)Eingangssignale2Strom +3Masse −4Spannung +5Nicht belegt67Verbindung für die GerätekonfigurationSicherheitsverbindung89

Pagina 28

9Anforderungen an die StromversorgungBevor Sie das Gerät an die Stromversorgung anschließen, überprüfen Sie anhand der Typenbezeichnung, ob diese den